THE 5-SECOND TRICK FOR SLIP RESISTANCE INSPECTION SERVICES

The 5-Second Trick For Slip Resistance Inspection Services

The 5-Second Trick For Slip Resistance Inspection Services

Blog Article



ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6

When it concerns ensuring safety in business, commercial, and property areas, slip resistance testing is a critical factor. At ATTAR (Advanced Technology Testing & Research), we focus on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to help services and homeowner reduce dangers and adhere to security requirements.

With advanced devices such as the pendulum slip test device and moisture meter for concrete, we offer accurate and independent slip testing services across Australia. Our knowledge covers ASTM F2170 compliance, R Score assessments, P Score tiles, and more, ensuring your floors meet the greatest security standards.

Why Slip Resistance Testing is Necessary


Slips and falls are amongst the leading causes of work environment and public injuries. Proper slip testing assists recognize harmful surface areas before accidents happen. Whether you need damp pendulum test examinations or pendulum test for slip resistance, ATTAR provides accurate results to enhance security.

Secret Services Provided by ATTAR


1. Floor Slip Resistance Testing

- Pendulum slip test (AS 4663).
- R Rating and P Rating tiles evaluations.
- Independent slip testing services for compliance.

2. Concrete Moisture Testing

- Slab moisture test utilizing sophisticated moisture meter for concrete.
- ASTM F2170 compliant evaluations.
- Concrete slab moisture testing to prevent floor covering failures.

3. Luminance Contrast Testing

- Guarantees visibility for visually impaired people.
- Complies with Australian ease of access standards.

4. On-Site & Lab Testing

- Slip test maker for accurate on-site evaluations.
- Wet pendulum test for damp surface area slip resistance.

Understanding Slip Resistance Rankings: R Score vs. P Rating


When conducting slip resistance testing, 2 essential classifications are utilized:.

- R Score (Ramp Test - DIN 51130)
Measures slip resistance under lubricated conditions, frequently used in Europe.

- P Ranking (Pendulum Test - AS 4586)
Evaluates dynamic friction utilizing a pendulum test slip resistance device, widely embraced in Australia.

ATTAR provides independent slip testing to figure out whether your flooring meets the needed pendulum rating tiles requirements.

The Significance of Concrete Moisture Testing


Excess moisture in concrete slabs can cause floor covering failures, mold development, and adhesive degradation. Our concrete moisture testing services consist of:.

> ASTM F2170 compliant in-situ relative humidity testing.
> Moisture meter for concrete evaluations.
> Slab moisture test to guarantee optimum conditions for floor installations.

By detecting moisture problems early, we help avoid costly repair work and ensure lasting flooring performance.

Luminance Contrast for Availability Compliance


Appropriate luminance contrast is vital for visually impaired people to navigate areas safely. ATTAR assesses:.

> Stair edges.
> Door frames.
> Handrails.
> Tactile indicators.

Our click here assessments make sure compliance with Australian Disability Standards (AS 1428.1).

Why Pick ATTAR for Slip Resistance & Moisture Testing?


> NATA Accredited (where applicable).
> Advanced Testing Devices (pendulum slip test, moisture meters).
> Nationwide Service Protection.
> Fast & Trusted Reporting.

For expert slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.

Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.

Typical Applications of Slip Resistance Testing


1. Commercial & Retail Spaces

Shopping centres, restaurants, and workplaces need safe flooring to prevent client and staff member injuries. Our pendulum slip test ensures compliance with security guidelines.

2. Industrial & Warehouse Facilities

High-traffic commercial environments require durable, slip-resistant flooring. ATTAR's slip testing services assist keep workplace safety.

3. Health Care & Aged Care Facilities

Health centers and nursing homes should decrease slip risks. Our luminance contrast and slip resistance testing ensure safe mobility for clients and personnel.

4. Public Facilities

Footpaths, train stations, and government structures require independent slip testing to satisfy ease of access and security requirements.

How ATTAR Conducts Slip Resistance Testing


Step 1: Surface Assessment

We assess floor covering products and conditions (dry, damp, or infected).

Step 2: Pendulum Slip Test (AS 4663)

Using a slip test machine, we measure the dynamic coefficient of friction (DCOF).

Step 3: Wet Pendulum Test

Replicates slippery conditions to examine real-world slip threats.

Step 4: Reporting & Compliance Accreditation

In-depth reports with R Rating or P Rating tiles classifications.

The Science Behind Pendulum Slip Testing


The pendulum test slip resistance method involves a swinging arm with a rubber slider that mimics a foot's movement. The test measures:.

- Slip Potential Value (SPV).
- Pendulum score tiles classification (P0 to P5).

Higher ratings (P4/P5) indicate better slip resistance.

Moisture Testing for Concrete Floors: Preventing Failures


Moisture-related flooring failures can be costly. ATTAR's concrete slab moisture testing includes:.

- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete spot checks.
- Slab moisture test information analysis.

Conclusion


ATTAR (Advanced Technology Testing & Research) is Australia's relied on supplier of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With innovative technology like the pendulum slip test and moisture meter for concrete, we provide precise, independent, and certified testing services.

Ensure your residential or commercial property satisfies safety standards-- contact ATTAR today:.

44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.

By choosing ATTAR, you buy independent slip testing services, pendulum test slip resistance precision, and long-lasting floor safety solutions. Let us help you develop more secure, certified, and moisture-resistant environments.

Report this page